5.3 Distance between rail supports
▶
The maximum permissible distance between rail supports, as shown in the illustration,
must be observed.
5.4 Position of holes drilled for fastening the rail supports
@
Distance between anchors with
track support positioned on the
inside = 235 mm
;
Distance between anchors with
track support positioned on the
outside = 230 mm
=
Distance between track supports
with support positioned on the
inside = 144 mm
%
Distance between track supports
with support positioned on the
outside = 139 mm
&
Distance between anchors for
flush-cutting = 235 mm
(
Distance between track supports
for flush-cutting >144 mm
▶
The holes drilled for fastening the rail supports should be positioned as shown in the
above illustration.