Item number
Designation
Description
2330128
DST-CF 60 6kt -45
Normal-cutting flange
2330129
DST-CF 1 3/8''
Normal-cutting flange (USA ver-
sion)
221343
Hex screw M12×25 10.9
Clamping screw (inner flange,
normal cut)
Accessories for dry cutting
Item number
Designation
Description
2328064
DST-CF 60 6kt -45
Dry-cutting flange
2330151
DST-CF 1 3/8" 6kt
Dry-cutting flange (USA version)
2330152
DS BG65 dry
Blade guard (dry cutting)
2330153
Dust removal hood (set)
1.1-2.0
Dry-cutting set
4
Technical data
4.1 Saw head
Rated values guaranteed at an ambient temperature of max. 18 °C and at an altitude
of max. 2000 m above sea level.
Weight in accordance with EPTA-
Procedure 01
33.7 kg
Rated speed
118 /min … 940 /min
Rated voltage
380 V … 400 V
Performance is reduced with an AC
supply voltage of < 370 V.
AC frequency
50 Hz … 60 Hz
Mains connection (phase requirements)
3~ + PE
Rated current
16 A
Mains fuse rating
16 A
Generator power requirements
≥ 20 kVA
Leakage current
≤ 10 mA
Storage temperature
−25 ℃ … 63 ℃
Application temperature, ambient tempera-
ture
−15 ℃ … 45 ℃
At temperatures below zero, allow
the machine to warm up slowly be-
fore subjecting to load and drain
(blow out) the water from the cooling
circuit after use (a pump is supplied
for this purpose).
Use preheated water.
Cooling water flow rate
> 2 ℓ/min
Cooling water temperature
4 ℃ … 25 ℃
Cooling water pressure
2 bar … 6 bar