GigE Line Scan Camera
·
User Manual
17
Figure 7-2
View Reference Line Rate
For different models of camera, the image compression mode function may differ, and the
actual product you purchased shall prevail.
After enabling the image compression mode, the camera’ s line rate and frame rate are related
with exposure and camera sensor only.
7.2 Set Frame Timeout
The frame timeout function may differ be camera models.
If the frame timeout function is disabled, the camera outputs one frame image after its
outputted line quantity reaches the configured height value, and the camera will wait line
quantity data if the outputted line quantity does not reach the configured height value.
If the frame timeout function is enabled, the camera outputs one frame image after its
outputted line quantity reaches the configured height value in the configured frame timeout
time.
You can set Partial Frame Discard and Abandon Extra Image in Acquisition Control if the camera’s
outputted line quantity does not reach the configured height value in the configured frame
timeout time.
Table 7-1
Parameters Description
Partial Frame Discard
Abandon Extra Image Description
Disabled
Disabled
The camera outputs one frame image after it
finishes image complement.
Disabled
Enabled
The camera discards partial images and outputs
remaining images.