GigE Line Scan Camera
·
User Manual
83
Camera Type
Normal Image
Abnormal Image
Color Camera
Steps:
1.
Set Off as Parallax Direction if the image’s edge does not have pixel deviation.
2.
Set Parallax Direction according to actual conditions if the image’s edge has pixel deviation.
For the mono camera, if its upper sensor is closer to the measured objects, and select
Start Line as Parallax Direction. Otherwise, select End Line instead.
For the color camera, if its sensor’s B line is closer to the measured objects, and select
Blue as Parallax Direction. If its sensor’s R line is closer to the measured objects, and
select Red instead.
3.
Set Pixel Shift to have a best effect.
Figure 10-49
Set Parallax Direction and Pixel Shift