GigE Line Scan Camera
·
User Manual
29
Steps:
1.
Click Tool > GigE Vision Action Command.
2.
Select Network Interfaces to set the subnet that the command to be sent to.
3.
Enter the Device Key, Group Key, and Group Mask.
Figure 7-16
Set Action Command
The specific contents entered in Device Key and Group Key should be the same with those in
Action Device Key and Action Group Key of the Action Control feature. The bitwise AND operation
of the Group Mask against the Action Group Mask feature should results in non-zero.
4.
Enable Scheduled.
5.
Click
in Benchmark Camera to select one camera as benchmark camera. Once benchmark
camera is selected, other cameras keep time synchronization with it.
6.
(Optional) Enter Delay Time according to actual demands.
The delay time should NOT be shorter than the maximum time required to transmit the
command across the network.
When the benchmark camera receives the command, all the cameras will trigger certain
actions simultaneously after the specified delay time.