Chapter 12 Troubleshooting
Table 12-1
Troubleshooting
No. Trouble
Possible Reason
Solution
1
No
camera
found
when
running
the
MVS
client
software.
Camera is not started up
normally, or
network
cable
connection error.
Check camera power wiring
(observe the indicator), and check
network connection.
2
Camera connection error.
Camera and client software are
not in the same network
segment.
Use MVS IP Configurator tool to
find the camera and edit its IP
address.
3
Live view is black.
Lens aperture is set too large.
The camera’s exposure value
is too small.
Reduce lens aperture value
properly.
Increase
the
camera’s
exposure value, or enable
auto exposure mode.
4
Live view is normal, but the
camera cannot be triggered.
The trigger mode is not
enabled, or the trigger source
is incorrect.
Incorrect trigger wiring.
Check whether the trigger
mode is enabled and selected
trigger source is correct.
Check whether trigger wiring
is correct.
5
A bi-directional configurable
line signal is selected as Line
Selector, and Line Mode is
Input currently. Why Line
Mode cannot be set as Strobe
The bi-directional configurable
line signal is selected as trigger
source
in
one
of
line
trigger/frame
trigger/shaft
encoder
control/
frequency
converter control settings.
Set other line signals as trigger
source in line trigger/frame
trigger/shaft encoder control/
frequency
converter
control
settings all.