GigE Line Scan Camera
·
User Manual
96
Parameter
Read/Write Description
GEV Heartbeat Timeout (ms)
Read and
write
It indicates the current heartbeat timeout in
milliseconds.
GEV Heartbeat Disable
Read and
write
It disables the GEV Heartbeat.
GEV Timestamp Tick
Frequency (Hz)
Read only
It indicates the number of timestamp ticks in 1
second (frequency in Hz).
Timestamp Control Latch
Read and
write
It latches the current timestamp value of the device.
Timestamp Control Reset
Read and
write
It resets the timestamp value for the device.
Timestamp Control Latch
Reset
Read and
write
It resets the timestamp control latch.
Timestamp Value
Read only
It is a read only element. It indicates the latched
value of the timestamp.
GEV CCP
Read and
write
It controls the device access privilege of an
application.
GEV MCP Host Port
Read and
write
It controls the port to which the device must send
messages. Setting this value to 0 closes the message
channel.
GEV MCDA
Read and
write
It controls the destination IP address for the
message channel.
GEV MCTT (ms)
Read and
write
It provides the transmission timeout value in
milliseconds.
GEV MCRC
Read and
write
It controls the number of retransmissions allowed
when a message channel message times out.
GEV MCSP
Read only
It indicates the source port for the message channel.
Содержание MV-CL021-40GM