GigE Line Scan Camera
·
User Manual
49
Logic 1
Output Level
Logic 0
Output Level
Internal
Logic
TDR
TDF
TF
TR
Figure 9-5
Output Logic Level
Table 9-4
Output Electrical Feature
Parameter
Symbol
Value
Output Rising Time
TR
0.06 μs
Output Falling Time
TF
0.016 μs
Output Rising Delay
TDR
0 μs to 4μs
Output Falling Delay
TDF
< 1 μs
9.3 Input Wiring
The camera can receive inputted signals via the hardware trigger to acquire images. The inputted
signals include differential signal and single-ended signal. The input wiring has two types according
to the camera’s pin definitions. The first type of input wiring corresponds to the first type of pin
definitions mentioned in Table 3-1, and the second type of input wiring corresponds to the second
type of pin definitions mentioned in Table 3-2.
Make sure that the hardware trigger signals have been configured as input signal.
Here we take one type of GigE line scan cameras as an example to introduce the input wiring.
Refer to the actual camera you got for specific appearance.
9.3.1 First Type of Input Wiring
Differential Signal
The wiring may differ by voltages of differential signal sources.