GigE Line Scan Camera
·
User Manual
34
Figure 7-21
Level Trigger in Frame Trigger
Set Trigger Activation in Line Trigger
In the line trigger mode, the trigger activation is related with Exposure Mode.
When Timed is selected as Exposure Mode, you can select Rising Edge or Falling Edge as
Trigger Activation, and Exposure Auto and Exposure Time determine the exposure time.
When Trigger Width is selected as Exposure Mode, you can select Level Low or Level High as
Trigger Activation, and exposure time is determined by the duration of the level signal only.
Figure 7-22
Trigger Width as Exposure Mode
The trigger width function may differ by camera models.
7.6.3 Trigger Delay
The trigger delay function allows the camera to add a delay between the receipt of trigger signal
and the moment the trigger becomes active. Its sequence diagram is shown below.