3.
Select Software as Trigger Source, and click Execute in Trigger Software to send trigger
commands.
Figure 7-5
Set Software Trigger
7.5.2 Set Hardware Trigger
If the camera enables the frame trigger or line trigger, you can select specific lines as trigger source
to enable hardware trigger. At this time, external devices send commands to the camera to acquire
images.
The specific hardware trigger sources may differ by camera models.
Steps:
1.
Click Acquisition Control > Trigger Selector.
2.
Select Frame Burst Start or Line Start as Trigger Selector, and On as Trigger Mode.
3.
Select specific lines as Trigger Source according to actual demands.
Here we take Line 0 as trigger source as an example. Refer to the camera you got for the actual
condition.
Figure 7-6
Set Hardware Trigger