GigE Line Scan Camera
·
User Manual
77
10.21 Set Flat Field Correction
The fat field correction function and specific setting method may differ by camera models.
The fat field correction (FFC) includes PRNUC correction and FPNC correction, and they are used to
improve the image uniformity that may be impacted by the sensor, light sources, external
conditions, etc.
10.21.1 FPNC Correction
The camera has completed FPNC correction by default and you do not need to set it again if the
camera has no FPNC correction function.
Steps:
1.
Click Shading Correction, and select FPNC Correction as Shading Selector.
2.
Click Execute in Activate Shading, and enable FPNC User Enable.
Figure 10-41
FPNC Correction
10.21.2 PRNUC Correction
The camera currently supports PRNUC (Photo-response Non-Uniformity Correction) function that
eliminates vertical line on the images. Two correction methods are available, including global
correction and ROI correction. The effect of PRNUC correction is shown blow.