T-CONTROL
9
45
Table 9. 1: Operation mode "Screed drying"
Bake out day
Flow set
temperature in
°C
If screed drying gets interrupted, resume
drying as follows:
1
25
Day of interruption
resume from day
2
30
0
– 15
1
3
35
16
16
4
40
17
– 23
17
5
– 12
45
24
– 28
24
13
40
29
29
14
35
15
30
16
25
17
– 23
10
24
30
25
35
26
40
27
45
28
35
29
25
30
0
figure 9. 1
: Flow must temperature in dependence of the bake out days at „Screed drying”
F
lo
w
s
e
t t
e
m
p
e
ra
tu
re
[
°C]
Bake out day