9
T-CONTROL
44
Term
Description
Unit
Time 1
1 - 3 times can be set. The second and third time can be added by the +.
Example:
▪
time 1:
08:00
– 10:00
▪
time 2:
15:00
– 21:00
▪
time 3:
00:00
– 00:00
-
08:00
– 11:00
Setting up individual hot water tank loading times of every weekday
-
By pressing the symbol Monday preset gets assigned to remaining
weekdays
-
Barrier times
4 5
Time 1
1 - 2 times can be set. The second time can be added by the +. Example:
see time program.
-
08:00
– 11:00
Setting up individual hot water tank loading times of every weekday,
when it will be not heated
-
By pressing the symbol Monday preset gets assigned to remaining
weekdays.
-
Menu "Heat curve"
Heat curve 1
1
2
Heat curve
-
Heat curve 2
1
2
Flow max.
temperature
Setting up the maximum flow temperature (30-95) of chosen heating
circuit.
°C
Root point
temperature
Setting up the minimum flow temperature (20-70) of chosen heating
circuit
°C
Flow temperature at
+10°C
Setting up the flow temperature (20-90) of chosen heating circuit at
+10°C outside temperature
°C
Flow set temperature
at adjustable outside
temperature
Setting up the flow temperature (25-95) of chosen heating circuit at a
adjustable outside temperature
°C
Adjustable outside
temperature
Setting up the outside temperature (-20 - 0) of chosen heating circuit
regarding flow must temperature
°C
Switch off temperature
Setting up the outside temperature (5-40)at which the chosen heating
circuit switches off if this temperature is exceeded.
°C
Operation mode „Screed drying“
After „Screed drying“ mode selection the shown flow temperature sequence gets started immediately. If a
lower flow temperature is desired, the flow temperature can be set up with the parame
ter „Flow max.
temperature“. If screed drying is interrupted caused by a fault (power breakdown, etc.), the program (after
fault correction) continues drying as shown automatically. A optional continuing day can be selected with
parameter „Screed days“. After screed drying completion the boiler will switch to "heating time mode". The
desired temperature can be set for each day (end of the program with setpoint= 0°C).
Содержание firematic PELLET 120
Страница 1: ...OPERATING INSTRUCTIONS Wood chips pellets heating system firematic PELLET 120 201 ...
Страница 19: ...Temperature manager 8 19 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 84: ...15 Annex 84 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Страница 85: ...Annex 15 85 Hydraulic recommendation 2 ...
Страница 86: ...15 Annex 86 15 2 Solar module Program 1 ...
Страница 87: ...Annex 15 87 Program 2 ...
Страница 88: ...15 Annex 88 Program 3 ...
Страница 89: ...Annex 15 89 Program 4 ...
Страница 90: ...15 Annex 90 Program 5 ...
Страница 91: ...Annex 15 91 Program 6 ...
Страница 92: ...16 Notes 92 16 NOTES ...
Страница 93: ...Notes 16 93 ...