Maintenance schedule
76
Item
Procedure
Ash container
Demount ash container cover and check
ash level and empty ash container if
necessary.
Control -
functioning
Check display, operation and faults list of
Control unit (see 0)
Restart T-Control
Control - faults
Open burning chamber door (1) or
remove ash container cover (2).
Check fault recognition and fault report
Check
if
fault
report
e.g.:
ASH
CONTAINER FAULT is shown
ID-fan
Function test of ID-fan using the
aggregate test
Check
ID-Fan
for
abnormal
or
conspicuous running noises
Thermal safety
device
Check thermal safety valve tightness
Safety valve
Check safety valve tightness
System pressure
Check system pressure
Minimum pressure: 1,5 bar (cold)
Maximum pressure: see boiler plate