T-CONTROL
9
35
Term
Description
Unit
Ash discharge
monitoring
Indicates the state of the sensor of the ash discharge monitoring.
If the indicator lamp lights up alternately during operation, the ash screw
works correct.
-
Fault central de-ashing
system
Display input error central ash discharge.
If the indicator lamp lights up a fault is active.
-
Heat exchanger
cleaning
Indicates the state of the heat exchanger cleaning:
If switch on green
Output active.
-
Magnetic valve
Indicates the state of the magnetic valve:
If switch on green
Output active.
-
fault E-filter
Indicates the output of the E-filter
-
fluegas-recirculation
flap
Indicates the output of the fluegas-recirculation flap
%
In-/Outputs
1 2 3 4 5
6
7
Back flow pump
Displays the state of the backflow pump:
If switch on green
Output active.
%
Back flow mixer open
Displays the state of the Backflow mixer:
If switch on green
Output active.
l/h
Back flow mixer close
Displays the state of the Backflow mixer:
If switch on green
Output active.
-
Output temperature
monitoring control
(TÜB)
Displays the state of the Output temperature monitoring control :
If switch on green
Output active.
-
Temp. monitoring
control storage room
Displays the state of the Output temperature monitoring control storage
room:
If the indicator lamp lights up, the maximum storage room temperature is
exceeded (the storage room temperature control sensor is active).
-
Sum annoyance
Displays the condition of the Sum annoyance:
If switch on green
Output active (active fault).
-
Operating alarm unit
Displays the condition of the Operating alarm unit:
If switch on green
Output active.
-
In-/Outputs
1 2 3 4 5 6
7
STL
Indicates the input of the safety temperature limiter (STL): If the indicator
lamp lights up, the STL has tripped.
-
Burner stop
Indicates the input burner stop. When the control lamp is lit, the system
has been stopped via the digital input (no burner release)
-
Additional input
Indicates the state of the additional input.
▪
If the indicator lamp lights up, the additional input is active (there is an
error)
At the additional input, the message of an external unit (CO detector,
extinguishing water tank, system pressure monitoring, etc.) can be
detected, for example.
-
Menu
"Operating hours"
Operating hours 1
1
2
Nominal load
Displays system operation hours during nominal load phase (95 -100%)
h
Modulation
Displays system operation hours during modulation phase (94-31%)
h
Part load
Displays system operation hours during part load phase (<30%)
h
Scorch- /burn out
Displays system operation hours during burning, born down and burnout
phase
h
Содержание firematic PELLET 120
Страница 1: ...OPERATING INSTRUCTIONS Wood chips pellets heating system firematic PELLET 120 201 ...
Страница 19: ...Temperature manager 8 19 Fig 8 6 Example temperature manager when time mode without difference ...
Страница 84: ...15 Annex 84 15 ANNEX 15 1 Additional boiler module Hydraulic recommendation 1 ...
Страница 85: ...Annex 15 85 Hydraulic recommendation 2 ...
Страница 86: ...15 Annex 86 15 2 Solar module Program 1 ...
Страница 87: ...Annex 15 87 Program 2 ...
Страница 88: ...15 Annex 88 Program 3 ...
Страница 89: ...Annex 15 89 Program 4 ...
Страница 90: ...15 Annex 90 Program 5 ...
Страница 91: ...Annex 15 91 Program 6 ...
Страница 92: ...16 Notes 92 16 NOTES ...
Страница 93: ...Notes 16 93 ...