1
15
Flame
monitoring
(burning
chamber
temperature)
If the burning chamber temperature fluctuates
greatly during operation, the boiler will switch off.
Freezing protection
If the freezing protection operates, the back flow
bypass pump will switch on only if the boiler is in
operating mode “HEATING OFF” or “BURNER
STOP”. Otherwise (freezing protection disabled)
the boiler will start up and heat up to minimum
boiler temperature 65 °C.
Lambda control
The amount of material and the rotation speed of
the ID-fan are controlled by the lambda control.
The control is able to detect marginal deviations of
the fuel quality and induces a combustion
improvement.