11
Maintenance schedule
78
11.3
Biannual inspection
Item
Procedure
Heat exchanger
Demount top boiler cover (1)
Unscrew
and
remove
heat
exchanger
insulation cover
Remove deposit and check heat exchanger
visually for damages and wear.
Remove lower rear panel (3)
Remove the rear cover of the heat exchanger
(4)
Remove deposit at turbulator holder visually
for damages and wear
Conduct function test of heat exchanger using
the aggregate test