ERS COMPACT
3.5.3.1
Sub menu “Settings”
Th is sub menu can be accessed directly from the main screen by tapping the Settings button.
Group
Parameters & description
Presets
U, I, P, R
Presetting of all set values via on-screen numeric pad.
Protection
OVP, OCP, OPP
Adjust the thresholds of the protections
Limits
U-max, U-min etc.
Define the adjustment limits (find more information in
“3.5.4. Adjustment limits”
)
User events
UVD, OVD etc.
Define supervision thresholds which can trigger user defined events (find more information
in
“3.7.2.1. User defined events”
)
General
Allow remote control
If remote control is allowed, the device can’t be controlled remotely over either the digital
or analog interfaces. This situation will be shown as “
Local
” in the status area on the main
display. Also see section
1.9.6.1.
R mode
Activates or deactivates the internal resistance control. If activated, the resistance set value and
actual will be shown the main screen. For details refer to
“3.3.4. Internal resistance regulation
(source mode)”
and
“3.5.6. Manual adjustment of set values (standard models)”.
Analog interface Range
Selects the voltage range for the analog set values, actual values and reference voltage output.
•
0...5 V
= Range is 0...100% for set /actual values, reference voltage will be 5 V
•
0...10 V
= Range is 0...100% for set /actual values, reference voltage will be 10 V
Also see
“3.6.4. Remote control via the analog interface”
REM-SB Level
Selects how the input pin REM-SB of the analog interface shall be working regarding levels
(see
“3.6.4.5. Analog interface specification”
) and logic:
•
Normal
= Levels and function as described in the table in
3.6.4.5
•
Inverted
= Levels and function will be inverted
Also see
“3.6.4.7. Application examples”
REM-SB Action
Selects how the input pin REM-SB of the analog interface shall operate regarding the DC
terminal condition outside of analog remote control:
•
DC Off
= the pin can only switch the DC power stage off
•
DC On/Off
= the pin can switch the DC power stage off and on again, if it has been switched
on before from a different control location
Pin 6
Pin 6 of the analog interface (see section
3.6.4.5
) is by default assigned to signal both device
alarms OT and PF. This parameter allows to also enable signaling only one of both (3 possible
combinations):
•
Alarm OT
= Signals only alarm OT
•
Alarm PF
= Signals only alarm PF
•
Alarm PF + OT
= Default, signals either PF or OT