Heinzinger electronic GmbH
Phone: +49 (0) 8031 2458 0
www.heinzinger.com
Anton-Jakob-Str. 4, 83026 Rosenheim
Fax: + 49 (0) 8031 2458 58
Germany
Page 55
ERS COMPACT
3.5
Manual operation
3.5.1
Switching on the device
The device should, as far as possible, always be switched on using the rotary switch on the front of the device.
Alternatively this can take place using an external cutout (contactor, circuit breaker) of suitable current capacity.
After switching on, the display will first show some device related information (model, firmware versions etc.) and
then a language selection screen for 3 seconds. A few seconds later it will show the main screen.
In the “
Settings
” menu (also see section
“3.5.3. Configuration via the menu”)
in the group “
DC terminal
” is an op-
tion “
State after power ON
” in which the user can determine the condition of the DC power stages after power-up.
Factory setting here is “
Off
”, meaning that the DC power stage on power-up are always switched off. “
Restore
”
means that the last condition will be restored, either on or off. All set values are always saved and restored.
For the time of the start phase the analog interface can signal undefined statuses on its digital
outputs. This must be ignored until the device has finished booting and is ready to work.
3.5.2
Switching the device off
On switch-off the last condition of the power stage and the most recent set values are saved. Furthermore, a PF
alarm (power failure) will be reported, but can be ignored.
The DC power stage is immediately switched off and after a short while fans will shut down and after another few
seconds the device will be completely powered off.
3.5.3
Configuration via the menu
The settings menu is meant for the configuration of all operating
parameters which are not constantly required. The menu is ac-
cessed by finger touch on the
Menu
touch area, but only while
the DC terminal is switched off. See figure to the right.
While the DC terminal is switched on the settings menu will not
be shown, but some status information.
Menu navigation is also done by finger touch. Inside menus, all
values are adjusted using the numeric pad that pops up when
tapping a value.
Many settings are self-explanatory, others are not. Those will be
explained on the pages following.