18
QSEE6800
+
H Installation and Operation Manual
Chapter 2: Installation
These problems can be corrected by re-installing the firmware while in
Boot Loader mode, as described in the following pages. Before you
perform this procedure, check the appropriate readme file to confirm
which files are needed. Use care to ensure that you upload the correct
files to the intended module.
Follow these steps to upgrade a 6800
+
module in Boot Loader mode:
1. Remove the affected module from the 6800
+
frame.
Figure 2-7.
Buttons on a Typical Card Edge
2. Set the hex switch to F.
3. While pressing the navigation toggle switch down, reinsert the
module into the frame.
4. Download the most recent appropriate upgrade package from our
Web site or from your CD-ROM, and then unzip the upgrade
package.
5. If the affected module has not been discovered by your CCS
software application, enter Build mode, and then drag or copy and
paste the module’s device icon from the catalog folder into the
Network
or
Discovery
folder.
6. Right-click the device icon and then select
Properties
.
Hex switch (Mode
select rotary switch)
Navigation toggle
switch
Note
To successfully upgrade the
firmware, you must follow these
steps in the exact sequence
described.