Chapter 4 – Ways to Set Scale Parameters
Hardy Process Solutions HI 6200 Weigh Processor User Guide
42
IT Test Reduced
Hex value: 0x82
Decimal value: 130
Write the hexadecimal value 0x82 to the command register to perform an Integrated
Technician test with reduced voltage. This test requires an IT summing card.
Status Error code 1
Fail
Status code FF
cmd in progress
C2 Search
Hex value: 0x83
Decimal value: 131
Write the hexadecimal value 0x83 to the command register to force the module to search for
and read/update C2 data.
Status Error code 1
Fail
Status code FF
cmd in progress
WRITE CMD
Hex value: 0x92
Decimal value: 146
Set the value of a parameter. Write the hexadecimal value 0x92 in the command register 0,
the parameter ID number in the
ParameterID
register, and the desired value in the
ParameterValue
register of the output table.
Status Error code 1
Fail
Status Error code 0x0B
Value out of range too high
Status Error code 0x0C
Value out of range too low
Status Error code 0x0D
Not allowed
Status Error code 0x80
Invalid parameter ID
DRAFT