Chapter 4 – Ways to Set Scale Parameters
Hardy Process Solutions HI 6200 Weigh Processor User Guide
38
4.3.4 Configuration with AOP
Using the
EDS_AOP
file makes configuring the HI 6200 instrument fast and easy.
Note:
If the configuration is “enabled” in the AOP or configuration table, the
configuration table downloads into the instrument every time the connection is
cycled.
1. Open the
EDS_AOP
file and go to the
Configuration
section.
2. To use the configuration parameters, set the parameter
Enable/Disable Configuration
Table
to
Enable
.
3. Make any required changes.
4. Click
Apply
. The configuration table is downloaded to the instrument. The instrument
then uses the information in the table to configure its parameters automatically.
4.3.5 PLC Commands
The PLC can control the HI 6200 using the commands in Table 4-3. The sections following
the table provide detailed descriptions about the commands.
Table 4-3. Hardy Commands
Command Number
Command
(0x00)0
Read Parameter
(0x01)1
Zero Cmd
(0x02)2
Tare Cmd
(0x64) 100 dec
Cal Low Cmd
(0x65) 101 dec
Cal High Cmd
(0x66) 102 dec
C2 Cal Cmd
DRAFT