The RFID module is integrated into the touch protection cover together with the optical
RGB LED and connected to the Wallbox via a plug connection. This can be disconnected
for installation or maintenance of the charging station.
Please ensure that the
plug connection
is
made
at the touch guard during normal
operation and function testing!
Further information on the charging process can be found on page 19.
Operating status
Your cPH2 charging station is designed for maximum safety in operation and the most
reliable charging possible. Internal test routines detect any malfunction of the cPH2 and
the Wallbox is switched off immediately.
If a malfunction should occur in practice, it is indicated via the LED displays in the front
area of the cPH2. The following chapter describes how to recognize operating and error
conditions and what measures you can take to remedy the fault.
Status-LED
The LED status indicators on the front of the Wallbox show the current operating status.
For display purposes, the LEDs can be...
•
...light up (permanently on)
•
...flashing (1Hz)
•
...not light up (permanently off)
Status-LED
Description
Green
The Wallbox/charging point is ready for operation. The vehicle can
be connected.
Yellow
Vehicle is connected and ready to charge (or fully charged)
Blue
The vehicle is currently being charged.
Red
Error occurred during loading (notify technician)
Purple flashing
OCPP authentication phase (only for backend connection)
Green flashing
Update process (do
NOT
switch off the charging station)
Red flashing
Internal DC fault current detection has triggered. Disconnect
vehicle and try again.
Off
No power supply (check external fuses) /
Check internal control fuse (notify technician)
Installation and operating manual
cPH2
charging station
Version: 1.0.9
22