background image

Electrical installation of the charging station

DANGER!

Danger to life due to electric shock!

Before working on the cPH2 charging station:

Disconnect the power supply and ensure that it remains permanently 

disconnected during the work.

After completion of the mechanical installation, the charging station is ready to be 

connected to the mains. Only the basic connection of the power supply line is described 

below: The assembly and connection of optional accessories is not the subject of these 

instructions, but is described in the instructions for the respective component.

NOTE!

For the fuse protection of the Wallbox, one 

type A RCD

RCD type A

 (residual current circuit breaker with 0.03A tripping current) 

and a subsequent

 circuit breaker 32 A

*

, 3-pole

 (C characteristic 

recommended) must be pre-installed for each supply line.

**

Special case

:

In the case of a Wallbox with two charging points and only one supply line, 

it is mandatory to pre-install a 

type B or type EV RCD

 in the supply line. 

We therefore recommend connecting one supply line per charging point.

*

  A C16A or C20A, 3-pole is specified for the cPH2 1T11.

**

 Deviating country-specific standards (connection conditions) must be observed!

For the electrical assembly you need the following components:

• Allen key 4 mm (not included in the scope of delivery)

• Stripping pliers for supply cable (not included in scope of delivery)

NOTE!

The initial commissioning of the charging station 

MUST ALWAYS

 be 

carried out by a qualified installer: This person can determine the correct 

operation of the charging station or correct any malfunctions or 

installation errors.

Installation and operating manual 

cPH2

 charging station

Version: 1.0.9

15

Содержание cPH2 1T11

Страница 1: ...The smart Wallbox cPH2 Installation and operating manual Installation and operating manual cPH2 charging station Version 1 0 9 English ...

Страница 2: ...eCharge Hardy Barth GmbH Leinbergstraße 14 92262 Birgland Schwend Phone 49 0 9666 188 00 50 Fax 49 0 9666 188 00 31 Web www echarge de Mail support echarge de Installation and operating manual cPH2 charging station Version 1 0 9 2 ...

Страница 3: ...ilable accessories and equipment optional 12 Assembly and installation 13 Requirements for the assembly site 13 Wall mounting of the charging station 14 Electrical installation of the charging station 15 Commissioning and charging 18 Safety instructions for operation 18 Loading process 19 Charge control 21 RFID module optional 21 Operating status 22 Status LED 22 Malfunctions and solutions 23 Tech...

Страница 4: ...ated symbols carry the following meanings Danger Life threatening electrical voltages occur Actions marked with this symbol MUST NEVER be performed Caution Sections marked with this symbol indicate additional hazards that may result in damage to the device or other consumers Actions marked with this symbol must be performed by qualified personnel and with SPECIAL CARE Notice Sections marked with t...

Страница 5: ...non compliance of the assembly and manual instructions by usage of non authorized replacement parts or accessories or by deploying non qualified professional staff This charging station corresponds to the current state of the art and complies with all current safety requirements guidelines and standards The safety instructions in this manual are intended to ensure proper installation at the place ...

Страница 6: ...ally or visibly damaged the charging station does not function properly or has been damaged in some other way Also note the following The cPH2 is protected against spray and splash water according to IP 54 However it should not be installed in the immediate vicinity of flowing or jet water The cPH2 charging station must not be installed in an environment with danger for explosions EX area The char...

Страница 7: ...ticular it must be ensured that vehicles can be parked at the prescribed distance from the charging station for charging operation and can be connected to the charging cable without tension Make sure that the front housing cover of the charging station is always closed to prevent unauthorized opening of the housing DO NOT make any changes to the housing or the internal circuitry of the device Fail...

Страница 8: ...les after installation you must take the charging station out of operation immediately Contact the service department of eCharge The respective local regulations for the operation of electrical equipment apply at all times Introduction Thank you for choosing the cPH2 charging station from eCharge Hardy Barth GmbH With this Wallbox you invest in an innovative and future proof solution for the priva...

Страница 9: ...ox also allows 100 use of solar power from an existing photovoltaic system for charging your electric vehicle Furthermore in combination with a compatible smart energy meter such as our eCB1 MP the cPH2 enables dynamic load management for example to avoid peak loads or limit the maximum current when using multiple charging points simultaneously The two LED displays on the front of the housing info...

Страница 10: ...outside and inside of the housing CAUTION The charging station may only be opened by qualified personnel The model designation cPH2 xTyy and the values for the mains connection voltage mains frequency current are particularly relevant for identification For detailed information on the cPH2 charging stations please refer to the Technical data section on page 24 Installation and operating manual cPH...

Страница 11: ...livered fully assembled and tested All dimensions as well as the mounting points are shown in the following dimensional drawings Top and side view of the cPH2 series all dimensions in mm Installation and operating manual cPH2 charging station Version 1 0 9 11 ...

Страница 12: ...the following accessories for your cPH2 Wallbox For more information or information about available accessories and the further delivery program of eCharge please visit our website at www echarge de Components Description RFID module incl 5 x RFID cards Authentication and release of the loading process for an authorized group of users GSM communication module Backend connection e g management of m...

Страница 13: ... charging cable of the cPH2 The cable must NEVER be under tension when connected to the vehicle Requirements for the assembly site The cPH2 charging station was developed for indoor and outdoor use For proper charging you as the operator must observe the following specifications for the location as well as for the installation Observe all local regulations for electrical installations fire prevent...

Страница 14: ...ing template echarge de accessories or PDF not included in delivery or optionally available cPH2 drill plate as eCharge accessory Article 3M40777 If necessary spirit level not included in the scope of delivery Proceed as follows 1 Check the dimensions on the drilling template for correctness using a calibrated meter measure BEFORE marking and drilling the holes 2 Mark the four drill holes on the w...

Страница 15: ...r 32 A 3 pole C characteristic recommended must be pre installed for each supply line Special case In the case of a Wallbox with two charging points and only one supply line it is mandatory to pre install a type B or type EV RCD in the supply line We therefore recommend connecting one supply line per charging point A C16A or C20A 3 pole is specified for the cPH2 1T11 Deviating country specific sta...

Страница 16: ... the supply line from below into the corresponding cable gland Then clamp the stripped wires of the supply line into the supply line terminals according to the terminal labeling max 10 mm The underlined phases indicate the terminals for the right hand charging connection Incorrect connection of the wires can cause damage to the charging station Caution In the case of a Wallbox with two charging po...

Страница 17: ...kers of the cPH2 charging station switch position I ON 6 Reattach the housing cover to the cPH2 charging station 6 1 Reconnect the plug for the LED indicators and insert the Touch protection cover in 6 2 Hook the housing cover back onto the charging station from above 6 3 Hand tighten the two screws on the lower side of the housing cover 7 Finally activate the back up fuses installed in the supply...

Страница 18: ...rging cable to connect to your vehicle The type 2 charging socket of the cPH2 in accordance with IEC 62196 2 has three live contacts a neutral conductor a PE protective conductor and two signal contacts Control Pilot and Proximity Pilot which ensure safe connection and thus hazard free use As long as the plug of the external charging cable is not locked in the charging socket of the cPH2 no voltag...

Страница 19: ...ing coupling of the charging cable into the charging socket on the vehicle The vehicle must be parked so that you can easily reach the socket on the vehicle The cable must not be under tension during the charging process 4 if available on your model open the cover of a charging socket on the cPH2 and insert the type 2 charging plug NOTE If you equip your Wallbox with RFID authentication or an OCPP...

Страница 20: ...ng process is usually terminated only by the vehicle The LED STATUS changes from blue to yellow After the charging process is completed first pull the cable out of the socket on the vehicle and then if present out of the Type2 socket on the Wallbox If the vehicle is not 100 charged in this case please check the settings in your vehicle You usually have the option of setting a charge limit e g at 8...

Страница 21: ...ur website echarge de Our user interface is constantly being optimized and further developed so we can continue to provide you with new functionality even after you have purchased your charging station The control of a cPH2 with Salia board and a cPH1 with eCB1 Smart Controller is not possible on a common web interface RFID module optional The RFID module is an optional order option with the cPH2 ...

Страница 22: ...scribes how to recognize operating and error conditions and what measures you can take to remedy the fault Status LED The LED status indicators on the front of the Wallbox show the current operating status For display purposes the LEDs can be light up permanently on flashing 1Hz not light up permanently off Status LED Description Green The Wallbox charging point is ready for operation The vehicle ...

Страница 23: ...l control fuse has tripped Error of the internal 12V DC power supply unit Check internal 12V operating voltage or contact support if necessary Vehicle is not detected LED remains on green The charging cable is not correctly connected to the vehicle or the Wallbox Remove the charging plug from the vehicle and plug it in again make sure that the plug is correctly seated in the vehicle socket Check t...

Страница 24: ...cket release in case of mains voltage failure Type 2 20 A Type 2 32 A 2x Type 2 32 A Fuse Type 1T11 1T22 2T22 2T44 DC fault current detection electronic DC RCM IΔn DC 6 mA per charge point Welding Detection Error signal via LED indicators Circuit breaker required on site 16 A 3p 32 A 3p 2x C32 A 3p 2x C16 A 3p 2x 32 A 3p Residual current circuit breaker required on site RCD type A 40 A 30 mA 2x RC...

Страница 25: ...ackend connection Vehicle communication IEC 61851 1 Mode 3 and ISO 15118 Ready Conditions Standards Operating temperature 25 to 50 C Storage temperature 25 to 80 C Relative humidity 5 bis 95 non condensing Standards IEC 61851 1 IEC 61851 21 IEC 61851 22 Class of protection II Overvoltage category III Degree of pollution 3 Degree of protection IP54 Maximum Elevation 2000 m NHN Housing Product cPH2 ...

Страница 26: ...itions IEC 61851 1 Mode 3 Charging with specific charging plug in systems for electric vehicles with pilot and control contact IEC 61851 21 2 Requirements for on board chargers for electric vehicles with alternating current direct current supply DIN EN 61851 22 AC charging station for electric vehicles Protection class protection type Explanation Protection class II The charging station has protec...

Страница 27: ... claims This includes claims that are due to the following causes 1 deterioration due to normal wear and tear corrosion damage accident faulty storage or operation lack of reasonable and necessary maintenance 2 installation services of the Wallbox carried out by unauthorized persons by an unauthorized electrician installers not authorized by eCharge Hardy Barth GmbH or the customer himself 3 repai...

Страница 28: ...ases the manufacturer in cooperation with the local distributor will attempt to restore the proper function of the product Any costs incurred for the transport of the product shall be borne by the customer If the serial number has been removed from the Wallbox altered or made illegible through the fault of the customer all rights granted under the warranty conditions shall expire and only the stat...

Отзывы: