48
ALPHA
Air conditioning
The overpressure
Cold ambient temperature
Turn the AC thermostat knob off and back to
warning lamp lights
desired setting again
The circuit leakage
Leakage of refrigerant from the circuit Clean as described in section “maintenance”
warning lamp lights
The cooling capacity
Low air flow
Clean the evaporator
is poor
Restricted evaporator
Clean or renew the cab filters
Restricted condenser
Increase fan speed
No function at all
Fuse blown
Change fuse
Thermo fuse disengaged
Press in the red button on condenser
left hand side
Four wheel steering sensor
No signal from sensor
Distance between sensor
Adjust sensor
and disc is incorrect
Sensor defective
Renew sensor
Engine
Please see engine manual
Hydrostatic transmission
Machine will drive in
Neutral position on pilot handle
Adjust the linkage till neutral is correct
neutral position
linkage is faulty adjusted
Neutral position on the pump
See your HARDI dealer for pump adjustment
is faulty adjusted
Machine will not drive
Parking brake is engaged
Disengage parking brake
Feed pressure is low
Check feed pressure (brakes engaged)
The machine is moving
With SAPE engaged:
too slowly
Faults in the SAPE components,
See your HARDI dealer
sensors, valves etc.
With SAPE disengaged:
Feed pressure low
Check feed pressure (brakes engaged)
On hilly terrain:
High pressure valves set too low
Check high pressure valves setting
Internal leakage in
Check internal leakages on pump, motors etc.
pump/motors excessive
Problem
Probable cause
Control / remedy
Содержание ALPHA 2000
Страница 5: ......
Страница 6: ......
Страница 7: ......
Страница 9: ......
Страница 16: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 27: ......
Страница 28: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 51: ......
Страница 52: ...52 ALPHA Notes...