background image

23

ALPHA

Tilting of the cab

The cab can be tilted for easy access during mainte-
nance jobs. An electric ram is available for this purpose.

1. Unfold the boom inner sections to improve access.
2. Fit the electric ram under the cab and secure with

lynch pins.

3. Connect the plugs between control box and the ram.
4. Connect the terminal clips to battery: Red to pos. (+)

and black to neg. (-).

5. Remove the two bolts in left hand-side front and back

of the cab.

6. Remove the transport bracket cross sectional bar

(only on OLH booms with Air conditioning).

7. The cab is now tilted.
8. The cab is lowered in reverse order.

IMPORTANT!

Always remember to fit and tighten the

two securing bolts again. Never drive with the electric
ram connected, as it will disable the cab rubber suspen-
sion.

Maintenance

To keep the machine in good, safe and reliable working
order, as well as keeping the maintenance and repair
costs to a minimum it is essential to follow the preven-
tive maintenance programme given hereafter.

Lubrication table

C

omponent

Capacity

Lubricant

DEUTZ engine: 4 cyl.

9.5 litres

TOTAL Rubia XT

6 cyl.

15.5 litres

Castrol Powermax
Shell Myrina M
Mobil

®

Delvac

®

Hydrostatic transmission
Hydraulic system

60 litres

TOTAL Equivis 46

Hydrostatic steering

Castrol Hyspin AWH 46
Shell Tellus T46
Mobil

®

DTE

®

15 M

Diaphragm pump

-

Lithium based ball bearing (grease
nipple) grease, NLGI No. 2-2.5:
TOTAL Multis EP 2
CASTROL LMX Grease
Shell HD Retinax MS
Mobil

®

Mobilux EP 2 NC

Chassis and boom

-

Lithium based grease with grease
nipples molybdæniumdisulfide and
graphite:
Castrol Molymax
Shell SAS 4000
Mobil

®

Mobilgrease Special

Oil lubrication points

-

TOTAL Transmission TM
SAE 80W/90
Castrol EPX 80/W90
Shell Spirax 80W/90
Mobil

®

Mobilube

®

80W/90

Engine cooling system:

Deutz coolant anti-freeze, 45%

4 cyl.:

11 litres

Castrol anti-freeze 50%

6 cyl.:

15 litres

Glycoshell, 50%
Mobil, 50%

Fuel and lubricants storage

Always store fuel and lubricants clean, dry and cool -
preferably by constant temperature - to avoid contami-
nation by dirt and condensed water.

When having refilled the fuel storage tank, allow sedi-
mentation of possible dirt, condensed water and sludge
- wait 24 hours before refilling the sprayer fuel tank.
Drain water and sludge from storage tank once a year, if
possible.

Keep oil filling jugs and hoppers clean.

B

A

C

T060-0033

T060-0034

Содержание ALPHA 2000

Страница 1: ...ilable in certain countries only can be shown Please pay attention to para graphs dealing with precisely your model Published and printed by HARDI INTERNATIONAL A S EC Declaration of Conformity Manufa...

Страница 2: ...Operational problems spraying equipment 44 Technical specifications 46 Contents Foreword 2 Use of the sprayer 2 Safety precautions 2 Roadworthyness 4 Plant protection chemicals 4 Identification plates...

Страница 3: ...struction book remains un clear after reading it contact your HARDI dealer for further explanation before using the equipment Use the handholds and steps when getting on and off the machine to prevent...

Страница 4: ...move soaked clothing instantly and wash with soap and water in stantly Plant protection chemicals will penetrate the skin and affect your health Consult chemical label regarding precautions to be take...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ...h 16 Working lamps switch 17 Wind screen washer switch 18 Auxiliary lights switch 19 Not used 20 Screen wash reservoir 21 On off switch for HARDI PILOT 22 Fuse box 23 Cab interior lamp 24 Fan control...

Страница 9: ......

Страница 10: ...itched on when at least the position lamps are switched on The working lamps must be switched off on public roads Wind screen washer switch Controls the windscreen washer Use plenty of screen wash bef...

Страница 11: ...ed by means of the engine coolant The warm air is distributed via the adjustable air flow louvres placed in the floor of the cab and will ensure effective heating of the cab and defrosting of the wind...

Страница 12: ...hat All oil and fluid levels are correct Nobody is carrying out service or repair jobs on the machine All protection guards are properly fitted Parking brake is activated Pilot lever is in neutral pos...

Страница 13: ...n slippery condi tions where change in weight distribution will cause spinning front wheels IMPORTANT Range 3 should not be used for continu ous driving When conditions are back to normal switch to ra...

Страница 14: ...on oil e g CASTROL RUSTILLO or SHELL ENSIS FLUID on all metal parts in order to avoid chemicals and fertilizers to discolourate the enamel Avoid to apply oil on windows lamps markings and rub ber part...

Страница 15: ...he O rings be fore reassembling the filter and replace if damaged Use of MANIFOLD valve system The following pictograms and colours are used for the visualizing the function of the MANIFOLD valves Gre...

Страница 16: ......

Страница 17: ...illing Device In some areas it is prohibited to fill from open water reservoirs lakes rivers etc It is recommended only to fill from closed reservoirs mobile water tanks etc to avoid contamination WAR...

Страница 18: ...CONTROL UNIT WHILE DRIVING 11 To close the entire boom operate switch A This takes the pressure from the pump The liquid will then return to the tank via the return system and serve as agitation The d...

Страница 19: ...MPORTANT Rinsing device uses spray liquid to rinse containers for concentrated chemicals Always rinse the chemical containers with clean water several times until they are clean before disposal 9 Enga...

Страница 20: ...B unless the multi hole nozzle is covered by a container to avoid spray liquid hitting the operator IMPORTANT Rinsing device uses spray liquid to rinse containers for concentrated chemicals Always rin...

Страница 21: ...pray liquid residues in the spraying circuit for spraying the liquid in the field be fore cleaning the sprayer 1 Empty the sprayer as much as possible Turn the agi tation off and spray till air comes...

Страница 22: ...iquid in the field you have just sprayed 8 Repeat point 3 7 until the rinsing tank is empty WARNING The rinsing nozzles cannot always guarantee a 100 cleaning of the tank Always clean manually with a...

Страница 23: ...5 litres TOTAL Rubia XT 6 cyl 15 5 litres Castrol Powermax Shell Myrina M Mobil Delvac Hydrostatic transmission Hydraulic system 60 litres TOTAL Equivis 46 Hydrostatic steering Castrol Hyspin AWH 46 S...

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...th WARNING Do not detach all stabilizer rods at the same time The boom can fall out of the suspension and cause severe personal injury Break away OLH The function of the break away is to prevent or re...

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ...aporate Not maintenance free batteries 3 Check electrolyte level Fill with demineralized water till level reaches 10 mm above cells if levels are low 4 Connect battery charger terminal clips to batter...

Страница 35: ...upper arm 6 The lower arms must be disconnected simultane ously 7 Grease all grease nipples 8 Remove the lifting gear again Ball seat check renewal EC on off valve If the main ON OFF valve does not s...

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ......

Страница 41: ......

Страница 42: ......

Страница 43: ...te some extra time to the sprayer If chemical residues are left over in the sprayer for longer periods it can reduce the life of the individual components To preserve the sprayer intact and protect th...

Страница 44: ...se in the junction box Now manually turn the emer gency control knobs Towing In emergency situations the machine can be towed a short distance In case of a engine break down on pub lic road and the ma...

Страница 45: ...ve terminal at battery at vehicle with discharged bat tery This to avoid sparks near the battery when connecting the last cable to terminal Trouble shooting Operational problems spraying equipment In...

Страница 46: ...gauge Check for dirt at inlet of gauge Pressure dropping Filters clogging Clean all filters Fill with cleaner water If using powders make sure agitation is on Nozzles worn Check flow rate and replace...

Страница 47: ...print plate for dry solders or loose connections D A H Hydraulic system No boom movements Insufficient oil pressure Check oil pressure min 130 bar max 150 bar when activated Check hydraulic oil level...

Страница 48: ...ect Sensor defective Renew sensor Engine Please see engine manual Hydrostatic transmission Machine will drive in Neutral position on pilot handle Adjust the linkage till neutral is correct neutral pos...

Страница 49: ...ating Engine coolant Air conditioning Optional extra Air conditioning refrigerant R134 A Overall dimensions 18 24 m OLH 27 28 m OLH 24 28 m GVA 30 m GVA Overall length 7150 7320 7200 7490 Overall widt...

Страница 50: ...All units used in this manual are SI units In some occa sions Imperial units are used Use following factors to convert SI units to Imperial units SI unit Imperial unit Factor Weight kg lb x 2 205 Sur...

Страница 51: ......

Страница 52: ...52 ALPHA Notes...

Отзывы: