65
◼
Interface
◼
Power Supply
Standard
EIA RS485
Number of devices
31. Address setting: 1~99 range
Communication type
2 wire or 4 wire half-duplex
Synchronization
Start – stop synchronous mode
Communication order
None
Communication distance
Max 1.2 km
Communication rate
600 / 1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps
Start Bit
1 Bit
Data length
7 or 8 Bit
Parity
None, Even, Odd
Stop Bit
1 or 2 Bit
Protocol
PC-LINK, PC-LK-S, MODBUS ASCII, MODBUS RTU
Response time
Handling time + (RP.T X 10 ms)
Current output
Current output range: 4 - 20 mA DC Resistance load: less than 600 Ω
Accuracy : ±0. % of FS. (4 - 20 mA DC)
Resolution : Approx. 3,000
Output ripple : Max 0.1 % of FS. (p-p) (150 Hz)
Output renewal cycle time : 100 ms
Retransmission output
Retransmission signal: PV (Process value) / SV (S et value) /
MV (Volume of output) / SPS (Power supply for sensor)
S caling: PV (Process value) / SV (S et value)
●
Retransmission output
※SPS(Power supply for sensor): Retransmission output of PV/SV/MV can not be used when you use SPS.
Power supply voltage
100 - 240 V AC (90V ~ 250V)
Frequency
50 - 60 Hz
Power Consumption
Max 6.0W / MAX 10 VA
Insulation resistance
20MΩ min(at 500V DC) : Between primary terminal and secondary terminal
Between primary terminal and ground
Between ground and secondary terminal
Dielectric Strength
2300V AC 50/60 Hz for 1 minute : Between primary terminal and secondary terminal
Between primary terminal and ground
1500V AC 50/60 Hz for 1 minute : Between F.G terminal and secondary terminal
Power supply for sensor
24 V DC 20 mA Max (select between retransmission output or SPS)