Chapter 9 Programming
141
Count
(n): the number of repeated movements on a side
Interval
(d): the distance that the robot moved each time
Note
If you do not enter the coordinates, the repeat count or the interval will
not be displayed.
When the repeat counts are set, the intervals are automatically
calculated and displayed. The intervals are not editable.
Advanced commands for patterns
Sets the display of the currently executing index of the pattern, the moving index using
the variable, and the starting position.
Start at this position
: If 'Start at this position' is checked, the start position is set at the
initial position of the pattern.
Check Location
: While pressing this button, move to the position you entered.
Select a variable for monitoring
: If you want to know the current running index of the
pattern, you can use a numeric variable to monitor for the current moving index.
- Starting index: 0 Base
- After executing the pattern, the monitoring variable is automatically increased by 1.
Use the position to move as the setting for the variable
: Used to move to a specific position using a variable.
Variables are used together with monitoring variables.
If starting position and variable movement are used together, starting position is given
priority.
Содержание HCR-5
Страница 1: ...HCR 5 Collaborative Robot User Manual Aug 2019 V 2 001 ...
Страница 2: ......
Страница 14: ......
Страница 96: ...Chapter 8 Safety Settings 96 ...
Страница 101: ...Chapter 8 Safety Settings 101 3 Press the OK button ...
Страница 177: ...Chapter 12 Device Settings 177 B When the scanning location and the robot s location are shifted by X ...
Страница 188: ...Chapter 15 Maintenance 188 4 When the confirmation window appears press YES ...
Страница 192: ...192 Appendix B Certification Safety ...
Страница 193: ...193 ...
Страница 194: ...194 MD Machinery Directive ...
Страница 195: ...195 LVD Low Voltage Directive ...
Страница 196: ...196 EMC Electro Magnetic Compatibility ...
Страница 197: ...197 Cleanroom Body ...
Страница 198: ...198 Cleanroom Controller ...
Страница 199: ...199 Appendix C Dimensions for Installation ...
Страница 200: ...200 Appendix D Tool Flange Cross Section The tool flange is designed suitable for ISO9409 1 50 4 M6 ...
Страница 205: ......