D
A1
1
2
NOTE:
1. Be sure that the power switch is turned off when replacing parts.
2. The language on the LCD is English only.
Preparation
1. Shift the bobbin winder spindle to the right.
2. Turn the drop feed lever to the right (away from you) to raise the feed dog.
3. Slide the speed adjusting lever to the left.
4. Remove the presser foot and raise the presser bar lifter (at normal up position).
5. Set the needle bar at the highest position.
Before starting the diagnosis test,
Check or replace the following part(s) if nothing happens when the power switch is turned on:
1. The connectors are connected properly (refer to page 7)
2. Replace the circuit board A (refer to page 7)
3. Replace the power supply cord.
4. Replace the switching power supply.
When replacing the sewing lamps or the printed circuit boards, do not turn on the machine.
To start the diagnosis test:
1. While pressing the needle up/down and lock stitch
buttons, turn the power switch on.
The LCD screens display "----".
2. Press "1" key to enter the self-diagnostic mode.
HQ Stitch 710 Diagno
s
tic Test Appendix
Содержание HQ Stitch 710
Страница 1: ...Service Manual 05 29 18 HQ Stitch 710...
Страница 18: ...Oil Put a drop of oil on the following 1 The presser bar at the bottom bushing inside the left hinged cover 15...
Страница 24: ...Oil Put a drop of oil on the following 7 The hook felt under the needle plate and the bobbin case 21...
Страница 92: ...Appendix II Diagnostic Tests 89...