1.
Carefully hook your finger under
the loop of the brown flexible cable
and pull upward. Do not grab the
cream-colored connector, as this is
soldered to the board.
2.
Unplug the four sets of wires on the
upper-right side of the board. On all
wires excluding the flexible cable in step
#1, ideally grasp the connector and not
the wires to avoid cable damage.
Alternatively grasp the cable set. Never
pull on one single wire.
5
9
Printed Circuit Board A Removal
3.
Locate and remove the three Phillips
screws that hold the A board to the front
panel; then remove the board.
Содержание HQ Stitch 710
Страница 1: ...Service Manual 05 29 18 HQ Stitch 710...
Страница 18: ...Oil Put a drop of oil on the following 1 The presser bar at the bottom bushing inside the left hinged cover 15...
Страница 24: ...Oil Put a drop of oil on the following 7 The hook felt under the needle plate and the bobbin case 21...
Страница 92: ...Appendix II Diagnostic Tests 89...