14.09.2020
61 / 156
VARMAX -
Installation, Use and Maintenance
WARNING:
Keep a distance of 10 mm between the suction nozzle and the metal
mesh. Any rubbing of the boiler tube may cause damage.
NEVER USE A METAL BRUSH.
WARNING:
Replace the seal under the clamp on the burner tube.
Refitting:
- Put the burner tube into the spool piece (be careful not to rub the metal mesh
on the spool piece). A directional pin enables the burner tube to be correctly
positioned.
- Position the clamp (the word "UP" must be visible and the inner lug must be
positioned on the rear axis of the boiler - see
47)
- Position the burner tube's removal / mounting tool in the slots in the clamp.
- Compress by pushing downwards and rotate the tool in a clockwise direction
to lock the tube (see
47).
- Check the seal on the spool piece's cover and replace if necessary.
- Position the cover over the spool piece.
- Screw the cover onto the spool piece using the screws (tightening torque =
5 N.m).
- Refit the 2 electrode blocks.
WARNING:
Check the different seals after mounting. If using a foaming product, be
careful of the ionisation electrode's electrical connection.
Содержание VARMAX 120
Страница 11: ...14 09 2020 11 156 VARMAX Installation Use and Maintenance ...
Страница 44: ...44 156 00BNO9168 I U0606551 VARMAX Installation Use and Maintenance figure 33 Electrical wiring diagram ...
Страница 125: ...14 09 2020 125 156 VARMAX Installation Use and Maintenance ...
Страница 155: ...14 09 2020 155 156 VARMAX Installation Use and Maintenance ...