Page 13
UPB Device Configuration (using UPStart):
HAI recommends the following settings for UPB Switches and Keypad Controllers for use with OmniLT.
With the PCS Serial PIM powered-up and connected to a PC, start the PCS UPStart application. Open an existing or create a new
network. Next, open the Link Name table by selecting “Network >> Link Names…”. Then, press the “New” button and define the
following 10 Links:
Link Id:
Link Name:
1.
241
Switch Off
2.
242
Switch On
3.
243
Switch 1/On
4.
244
Switch 2/Off
5.
245
Switch 3/A
6.
246
Switch 4/B
7.
247
Switch 5/C
8.
248
Switch 6/D
9.
249
Switch 7
10.
250
Switch 8
For each UPB Wall Switch:
Select a wall switch from the list of available devices. Click the “Transmit Component” tab and set the Transmit Components as
follows:
1.
For Rocker Top, select the “Switch On” Link
and set the mode to Status Button.
2.
For Rocker Bottom, select the “Switch Off”
Link and set the mode to Status Button.
3.
Under Options, set Transmit Type to Link
Packet, Transmission Attempts to 2, and
DO NOT
check "Report light level after
rocker switch is pressed".