background image

 

Page 4 

 

Lutron RadioRA RS-232 Interface (RA-RS232) 

OR

 Chronos System Bridge and Timeclock (RA-SBT-CHR): 

The RS-232 Interface allows for integration with HAI controllers.  The Chronos bridges two RadioRA systems and provides 
an RS-232 interface for integration with HAI controllers. 

 

 

Lutron RadioRA Switches, Dimmers, and Master Controls: 
Available from Lutron distributors. 

 
 

Control 

 
OmniLT can control up to 16 RadioRA devices.   
 
Each RadioRA Switch and Dimmer has its own Unit Number (1-16), which corresponds to the assigned Zone.  Each RadioRA Master 
Control has its own Unit Number (1-16), which corresponds to the assigned Master Control Number.   
 
It is possible for a Switch or Dimmer to have the same Unit Number (1-16) on the HAI system.  A Switch or Dimmer may be assigned 
to Zone 1 while a Master Control may be assigned to Mater Control Number 1.  In this case, both the Switch (or Dimmer) and the 
Master Control, will correspond to Unit Number 1. 
 
RadioRA devices can not share the same House Code with other PLC (Powerline Carrier) devices, such as X-10.   
 
RadioRA devices can share the same House Code with ALC devices.  Any unit number that is not being used for an ALC Switch 
Module may be used for a RadioRA device.  ALC Switch Modules and RadioRA devices can not be assigned to the same unit 
number. 
 
 

Controlling RadioRA Units 

 
Use the control menu when controlling RadioRA Switches and Dimmers.  To enter the control menu, from the top-level display or 
from the main menu, press the 1 (CTRL) key on the console keypad.  OmniLT will automatically display the first named item in that 
list.  Use the down arrow key to scroll through the list.  
 
After the unit has been selected, press the ' # ' key.  For RadioRA units, the console will display: 
 

Entry Lights 
0=OFF 1=ON 2=DIM 3=BRT 

 

   

 

   

 

Entry Lights

 

4=LVL 6=RMP 9=TIM #=STA

 

 
Press the 0 (OFF) to turn the selected unit off or the 1 (ON) key to turn the selected unit on. 
 
The 2 (DIM) key and 3 (BRT) key does not affect RadioRA units.   
 
Press the 4 (LVL) key to set the desired lighting level of the selected unit.  Enter a number (0-100) to indicate the lighting level 
(intensity) of the unit. 
 
The 6 (RMP) key does not affect RadioRA units. 
 
Press the 9 (TIM) key to time the selected unit (On or Off).  Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18 hours. 
 

 

Содержание OmniLT

Страница 1: ...Temperature sensors can be used for outdoors or in attics garages greenhouses basements wine cellars coolers and freezers The temperature can be displayed on the console or spoken over the telephone...

Страница 2: ...Page 2...

Страница 3: ...multiple RadioRA Switches and Dimmers with one command To control more than one device at one time Phantom Buttons are recommended A Zone is any individual RadioRA Switch or Dimmer A RadioRA System h...

Страница 4: ...such as X 10 RadioRA devices can share the same House Code with ALC devices Any unit number that is not being used for an ALC Switch Module may be used for a RadioRA device ALC Switch Modules and Radi...

Страница 5: ...n t explicitly send an All On command to those units If the House Code All On or House Code All Off setup item is set to No OmniLT will not change the status of each unit on the House Code Executing P...

Страница 6: ...default setting for HC 1 Format is 1 House Code 1 All Off This feature allows you to choose if House Code 1 will respond to the All Off command The default setting for HC 1 All Off is Yes HC 1 ALL OFF...

Страница 7: ...ctivated event Additionally you can specify that the event will only activate when a RadioRA Switch or Dimmer is turned on or off or if a button is pressed on a Master Control You are first prompted t...

Страница 8: ...Controlling RadioRA Units in this document Program Phantom Button Commands 4 ALL OmniLT can execute a Phantom Button command to set a lighting scene Press the 4 ALL key to execute a Phantom Button com...

Страница 9: ...rk ID that serves to link all of the switches modules and keypad controllers to each other and to the OmniLT controller Under the Network ID each device has a unique address The address is used to sen...

Страница 10: ...PB UPStart for optimal communications with the OmniLT controller Note Although the UPB protocol is extremely robust and less susceptible to powerline conditions for professional installations HAI reco...

Страница 11: ...tate is then displayed Entry Lights STATUS 67 Note When a UPB signal is received over the powerline OmniLT will automatically update the status of the device All On Off UPB devices are not affected by...

Страница 12: ...de rate and Wall Switch 2 to go to a different level at a different fade rate The ability to send more than one device to its preset level at a preset fade rate with a single command is known as activ...

Страница 13: ...Switch Off 2 242 Switch On 3 243 Switch 1 On 4 244 Switch 2 Off 5 245 Switch 3 A 6 246 Switch 4 B 7 247 Switch 5 C 8 248 Switch 6 D 9 249 Switch 7 10 250 Switch 8 For each UPB Wall Switch Select a wa...

Страница 14: ...ontrol settings For complete control of the LEDs by the OmniLT controller select Do Nothing under When this indicator comes on for each Indicator and uncheck all Group options For the 6 Button Keypad...

Страница 15: ...Null Null Null No Command Null K Switch 7 Custom Button Null Null No Command Null Null Null No Command Null L Switch 8 Custom Button Null Null No Command Null Null Null No Command Null Transmit Type L...

Страница 16: ...pose Mode and UPB transmission format HC 1 FORMAT 1 1 EXTENDED CHNG To change format for House Code 1 press the key then use the arrow keys to scroll through the list of formats Press the key to selec...

Страница 17: ...presses and receive Links press the key to bring up a menu of event button types BUTTON TYPE 1 CTRL 2 SEC 3 ZONE 4 ALL 5 ALARM 6 X 10 7 MISC 8 MSG Control Unit Event UPB Switch Press Event Buttons 1...

Страница 18: ...roller 8 Button Keypad Controller 1 2 On Button E 2 3 Off Button F 3 4 A G 4 5 B H 5 6 C I 6 7 D J 7 8 K 8 9 L Receive Link Event 4 ALL OmniLT can receive arbitrary Links from devices on the UPB netwo...

Страница 19: ...er when the A button on that keypad controller is pressed This program can also be used to illuminate the G button on an 8 Button Keypad Controller when the G button is pressed Program Status Request...

Страница 20: ...of units 1 4 WHEN LINK 1 ON RUN GROUP 1 WHEN LINK 2 ON RUN GROUP 1 WHEN LINK 3 ON RUN GROUP 1 WHEN LINK 4 ON RUN GROUP 1 When Link 1 4 On is received on the UPB network the Group 1 button macro is exe...

Отзывы: