Page 4
•
Lutron RadioRA RS-232 Interface (RA-RS232)
OR
Chronos System Bridge and Timeclock (RA-SBT-CHR):
The RS-232 Interface allows for integration with HAI controllers. The Chronos bridges two RadioRA systems and provides
an RS-232 interface for integration with HAI controllers.
•
Lutron RadioRA Switches, Dimmers, and Master Controls:
Available from Lutron distributors.
Control
OmniLT can control up to 16 RadioRA devices.
Each RadioRA Switch and Dimmer has its own Unit Number (1-16), which corresponds to the assigned Zone. Each RadioRA Master
Control has its own Unit Number (1-16), which corresponds to the assigned Master Control Number.
It is possible for a Switch or Dimmer to have the same Unit Number (1-16) on the HAI system. A Switch or Dimmer may be assigned
to Zone 1 while a Master Control may be assigned to Mater Control Number 1. In this case, both the Switch (or Dimmer) and the
Master Control, will correspond to Unit Number 1.
RadioRA devices can not share the same House Code with other PLC (Powerline Carrier) devices, such as X-10.
RadioRA devices can share the same House Code with ALC devices. Any unit number that is not being used for an ALC Switch
Module may be used for a RadioRA device. ALC Switch Modules and RadioRA devices can not be assigned to the same unit
number.
Controlling RadioRA Units
Use the control menu when controlling RadioRA Switches and Dimmers. To enter the control menu, from the top-level display or
from the main menu, press the 1 (CTRL) key on the console keypad. OmniLT will automatically display the first named item in that
list. Use the down arrow key to scroll through the list.
After the unit has been selected, press the ' # ' key. For RadioRA units, the console will display:
Entry Lights
0=OFF 1=ON 2=DIM 3=BRT
↓
Entry Lights
4=LVL 6=RMP 9=TIM #=STA
↑
Press the 0 (OFF) to turn the selected unit off or the 1 (ON) key to turn the selected unit on.
The 2 (DIM) key and 3 (BRT) key does not affect RadioRA units.
Press the 4 (LVL) key to set the desired lighting level of the selected unit. Enter a number (0-100) to indicate the lighting level
(intensity) of the unit.
The 6 (RMP) key does not affect RadioRA units.
Press the 9 (TIM) key to time the selected unit (On or Off). Timed commands may be from 1-99 seconds, 1-99 minutes or 1-18 hours.