Page 18
Press the 2 (SWITCH) key to select only when the top-rocker or bottom-rocker is pressed at a UPB Switch (locally at the UPB
Switch) or when a button is pressed on a UPB 6-Button or 8-Button Keypad Controller.
SWITCH:
0=OFF 1=ON 2-9=SW1-SW8
Press "0" to select only when the bottom-rocker (off) is pressed on a UPB Switch. Press "1" to select only when the top-rocker (on) is
pressed on a UPB Switch. Press "2-9" (see the Corresponding Switch Table) to select when that button is pressed on a UPB 6-Button
or 8-Button Keypad Controller. Press the ' # ' key to enter your selection.
Corresponding Switch Table
Switch
OmniLT
6-Button Keypad Controller
8-Button Keypad Controller
1 2
On
Button
E
2 3
Off
Button
F
3 4 A G
4 5 B H
5 6 C I
6 7 D J
7 8 K
8 9 L
Receive Link Event (4=ALL):
OmniLT can receive arbitrary Links from devices on the UPB network and run macros based on receiving that Link. For example, if
a 6-Button or 8-Button Keypad Controller is used to activate a lighting scene (by activating a Link), OmniLT also receives that Link
activation and can run a macro (i.e. adjust the room temperature, open/close window coverings, start sprinkler system, etc.).
Press the 4 (ALL) key to select the "When Command" for a receive Link activated event.
ALL
0=OFF 1=ON 2=SCN 3=LINK
When 3 (LINK) is selected:
ENTER
LINK
1-250
Enter a Link between 1 and 250.
LINK 1
0=OFF 1=ON 2=SET
When the corresponding Link and action (on, off, or set) is received on the UPB network, the macro is activated.