Page 6
RadioRA Setup
To configure various RadioRA items in the system, from the Set Up menu, press the 6 (MISC) key.
House Code 1 Format
House Code 1 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightolier's
Compose Mode, UPB, and RadioRA transmission format.
HC 1 FORMAT: 1
1=EXTENDED #=CHNG
¦
To change format for House Code 1, press the ' # ' key, then use the arrow keys to scroll through the list of formats. Press the ' # ' key
to select a new type
.
FORMAT NUMBER
DESCRIPTION
STANDARD
0 Preset
Dim
Command (X-10, X-10 Pro, PCS, etc.)
EXTENDED
1
Extended Code Level Command (Leviton)
COMPOSE
2 Compose
Mode
(Lightolier's
Compose)
UPB
3 Universal
Powerline
Bus
RADIO
RA
4 Lutron
RadioRA
The default setting for HC 1 Format is 1.
House Code 1 All Off
This feature allows you to choose if House Code 1 will respond to the “All Off” command. The default setting for
HC 1 All Off
is
Yes.
HC 1 ALL OFF: 1
0=NO 1=YES
¦
House Code 1 All On
This feature allows you to choose if House Code 1 will respond to the “All On” command. The default setting for
HC 1 All On
is Yes.
HC 1 ALL ON: 1
0=NO 1=YES
¦
Note:
RadioRA devices are not affected by the OmniLT “All On” or “All Off” command. However, if the House Code is set to
“Yes”, OmniLT will change the status of each unit on the House Code according to the setting.
Programming RadioRA
OmniLT can be programmed to run macros when a Switch or Dimmer is turned on or off locally or when a button (1-10) is pressed on
a Master Control.
Likewise, OmniLT can be programmed to control RadioRA Switches and Dimmers (on, off, and setting to a specific level) and
execute a Phantom Button.