Page 16
Setting the PCS Serial PIM to Message Mode
Step Operation
1
Press the Program pushbutton five (5) times quickly in a row.
2
The LED should start to blink green to indicate it is in Setup Mode.
3
Press the Program pushbutton ten (10) times quickly in a row.
4
The LED should start to blink red to indicate that the Factory Defaults have been set.
5
Press the Program pushbutton one (1) more time.
6
The LED should stop blinking to indicate that it is ready for normal operation.
*Repeat these steps after every use of the PIM with the PCS UPStart application.
UPB Setup
To configure various UPB items in the system, from the Set Up menu, press the 6 (MISC) key.
House Code 1 Format
House Code 1 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightolier's
Compose Mode, and UPB transmission format.
HC 1 FORMAT: 1
1=EXTENDED #=CHNG
¦
To change format for House Code 1, press the ' # ' key, then use the arrow keys to scroll through the list of formats. Press the ' # ' key
to select a new type
.
FORMAT NUMBER
DESCRIPTION
STANDARD
0 Preset
Dim
Command (X-10, X-10 Pro, PCS, etc.)
EXTENDED
1
Extended Code Level Command (Leviton)
COMPOSE
2 Compose
Mode
(Lightolier's
Compose)
UPB
3 Universal
Powerline
Bus
The default setting for HC 1 Format is 1.
House Code 1 All Off
This feature allows you to choose if House Code 1 will respond to the “All Off” command. The default setting for
HC 1 All Off
is
Yes.
HC 1 ALL OFF: 1
0=NO 1=YES
¦
House Code 1 All On
This feature allows you to choose if House Code 1 will respond to the “All On” command. The default setting for
HC 1 All On
is Yes.
HC 1 ALL ON: 1
0=NO 1=YES
¦
Note:
UPB devices are not affected by the OmniLT “All On” or “All Off” command. However, if the House Code is set to “Yes”,
OmniLT will change the status of each unit according to the setting.