7-24
SECTION 7 –
SPRAY SYSTEMS
On the Ag Leader Monitor:
•
Press the Boom Image (located on the
main “Run Screen”).
•
Press the top drop-down arrow (located
on the Boom Height Control Options
Screen) and select Soil or Crop Mode.
Sensitivity
Sensitivity is how responsive the system
is. The lower the number, the lower the
sensitivity. The higher the number, the higher
the response time and hydraulic demand.
NOTE: Default sensitivity setting is 5.
On the NORAC Pulse Monitor:
•
Press the Settings Button (wrench icon)
(located on the main “Run Screen”) to
navigate to the Settings Screen.
•
Press the Next Button (located next to
“Sensitivity”) and increase or decrease
system sensitivity values from 1-10.
On the Ag Leader Monitor:
•
Press the Boom Image (located on the
main “Run Screen”).
•
Press the Sensitivity Buttons (located on
the Boom Height Control Options
Screen) and increase or decrease system
sensitivity values from 1-10.
Target Height
Target Height is the height you desire the
boom to be set at when spraying.
NOTE: When operating in Soil Mode, the
Target Height is measured from the
spray nozzles to the soil. In Crop
Mode, the target height is measured
from the crop canopy to the spray
nozzles.
On the NORAC Pulse Monitor:
•
Press the Settings Button (wrench icon)
(located on the main “Run Screen”) to
navigate to the Settings Screen.
•
Press the Next Button (located next to
“Height”) and increase or decrease val-
ues to desired boom height.
On the Ag Leader Monitor:
•
Press the Boom Image (located on the
main “Run Screen”).
•
Press the Target Height Buttons (located
on the Boom Height Control Options
Screen) and increase or decrease values
to desired boom height.
Further Information
Refer to the NORAC or Ag Leader
manufacturer’s operation manual for
complete operating/calibration instructions,
troubleshooting information, and safety
precautions.
Refer to “Specifications” provided in the
Introduction Section
elsewhere in this
manual for information on GPS dimensions
on your machine.
Enabling NORAC through the
End Row Management Switch
-If Equipped
(Typical View - appearance may vary,
depending on model)
1. Program the End Row Management
Switch (located on the Hydrostatic Drive
Control Handle) through the Machine
Display.
Refer to “Machine Display” provided in
Section 3 - Cab elsewhere in this manual
for initial setup instructions.
Boom Height Control Options Screen