7-16
SECTION 7 –
SPRAY SYSTEMS
NORAC Sensors
The boom is equipped with five (5)
NORAC Sensors (two located at each folding
section, two located on each outer boom
extension, and one located on the transom)
that measure boom height above ground. The
sensors send a signal to the NORAC control
system allowing for position corrections to
keep the boom parallel to the ground and the
crop, giving you a more consistent spray
pattern.
Position Sensors
The level cylinders and main fold
cylinders are equipped with Position Sensors.
These sensors measure the linear stroke of the
cylinder, allowing the boom to be positioned
correctly when in Auto Fold mode.
The required specific motions exist to
provide smooth, efficient operation. The
programmed positions help prevent
mechanical damage to the boom due to
severe imbalance, unintended contact with
the ground, or improper fold sequence.
NOTE: The Position Sensors are factory-
positioned and should not require
calibration. Contact Hagie Customer
Support if boom positioning
assistance is needed.
Accumulators
The level and lift cylinders (located on the
transom) are equipped with multiple
Accumulators. These Accumulators act as a
“shock absorber” for the booms.
CAUTION
Placing an object beneath the NORAC
Sensors when the system is in automatic
mode may result in unintended
movement.
NORAC Sensor
-Typical View
Position Sensor
-Typical View
Содержание STS12i Combo