Table 1 Light wavelength and color (continued)
Sample color
Light absorbed
Wavelength (nm)
Blue
Yellow
580
Green-blue
Orange
600
Blue-green
Red
655
Measurement range
The measurement range of the instrument is 0 to approximately
1.50 Abs, but can be used up to a measurement range of 2.5 Abs if the
chemistry method supports that range.
If sample absorbances are more than 1.50 Abs:
1.
Dilute the sample or use smaller sample cells for the best linearity
and accuracy.
2.
If a smaller sample cell such as the 1-cm (10-mL) cell is used,
complete the calibration with the smaller sample cells.
Note: Absorbance increases with the increase of the sample cell pathlength.
Use a sample cell with a shorter pathlength to measure solutions with a
darker colored.
3.
Monitor the calibration curve to identify the measurement range for
a specific test.
The measurement range is the concentration range in which the
deviation from linearity is within acceptable limits.
Calibration curve
Calibration curves should ideally intersect the zero intercept for
absorbance. The zero intercept is the zero concentration point on the
calibration graph. When there is no analyte in the sample, the
absorbance will be zero.
A non-zero intercept (a positive or negative absorbance measurement
at zero concentration) can occur for many reasons. Factors that can
cause a non-zero intercept include the reagent blank, pH, temperature,
interfering species or turbidity differences between the zeroing solution
(blank) and the sample.
To adjust for a non-zero intercept caused by the reagent blank,
measure the absorbance of the prepared reagent blank and then
subtract it from the measured absorbance of the prepared sample. In
English
15
Содержание Pocket Colorimeter 2
Страница 8: ...Figure 2 Install the batteries 8 English ...
Страница 44: ...Abbildung 15 Küvettenausrichtung 1 Ausrichtungsmarkierung 2 Küvette 25 mm 10 ml 44 Deutsch ...
Страница 73: ...Figura 23 Orientamento celle campione 1 Segno di orientamento 2 Cella campione 25 mm 10 mL Italiano 73 ...
Страница 92: ...Figure 26 Installation des piles 92 Français ...
Страница 102: ...Figure 31 Orientation de la cuve à échantillon 1 Repère d orientation 2 Cuve à échantillon 25 mm 10 ml 102 Français ...
Страница 130: ...Figura 39 Orientación de la cubeta de muestra 1 Marca de orientación 2 Cubeta de muestra 25 mm 10 ml 130 Español ...
Страница 158: ...Figura 47 Orientação do recipiente de amostra 1 Marca de orientação 2 Recipiente de amostra 25 mm 10 mL 158 Português ...
Страница 176: ...Obr 50 Instalace baterií 176 Čeština ...
Страница 202: ...Figur 58 Isæt batterierne 202 Dansk ...
Страница 238: ...Afbeelding 71 Richting van de monsterkuvet 1 Richtingsteken 2 Monsterkuvet 25 mm 10 ml 238 Nederlands ...
Страница 284: ...Figur 82 Installera batterierna 284 Svenska ...
Страница 310: ...Kuva 90 Paristojen asentaminen 310 Suomi ...
Страница 337: ...Фигура 98 Поставяне на батериите български 337 ...
Страница 347: ...Фигура 103 Ориентация на кюветата 1 Маркировка за ориентацията 2 Кювета 25 mm 10 mL български 347 ...
Страница 366: ...106 ábra Az elemek behelyezése 366 Magyar ...
Страница 421: ...Рисунок 122 Установка батареек Русский 421 ...
Страница 450: ...Şekil 130 Pillerin takılması 450 Türkçe ...
Страница 476: ...Obrázok 138 Vkladanie batérií 476 Slovenský jazyk ...
Страница 503: ...Slika 146 Namestitev baterij Slovenski 503 ...
Страница 530: ...Slika 154 Umetanje baterija 530 Hrvatski ...
Страница 557: ...Εικόνα 162 Τοποθέτηση μπαταριών Ελληνικά 557 ...
Страница 581: ......