231
96-8000 Rev AC
May 2010
G
&
M
Codes
Settings
163 - Disable .1 Jog Rate
This setting disables the highest jog rate. If the highest jog rate is selected, the
next lower rate is automatically selected instead.
164 - Rotary Increment
This setting applies to the Rotary Index button on the EC300. It specifies the
rotation for the rotary table in the load station. It should be set to a value from
-360 to 360 degrees. For example, entering “90” will rotate the pallet 90° each
time the rotary index button is pressed. If it is set to zero, the rotary table will
not rotate.
167-186 Periodic Maintenance
There are 14 items that can be monitored, as well as six spare items, in the
periodic maintenance settings. These settings will allow the user to change
the default number of hours for each item when it is initialized during use. If
the number of hours is set to zero, the item will not appear in the list of items
shown in the maintenance page of current commands.
167 Coolant Replacement default in power-on hours
169 Oil Filter Replacement default in power-on hours
170 Gearbox Oil Replacement default in power-on hours
171 Coolant Tank Level Check default in power-on hours
172 Way Lube Level Check default in motion-time hours
173 Gearbox Oil Level Check default in power-on hours
174 Seals/Wipers Inspection default in motion-time hours
175 Air Supply Filter Check default in power-on hours
176 Hydraulic Oil Level Check default in power-on hours
177 Hydraulic Filter Replacement default in motion-time hours
178 Grease Fittings default in motion-time hours
179 Grease Chuck default in motion-time hours
180 Grease Tool Changer Cams default in tool-changes
181 Spare Maintenance Setting #1 default in power-on hours
182 Spare Maintenance Setting #2 default in power-on hours
183 Spare Maintenance Setting #3 default in motion-time hours
184 Spare Maintenance Setting #4 default in motion-time hours
185 Spare Maintenance Setting #5 default in tool-changes
186 Spare Maintenance Setting #6 default in tool-changes
187 - Machine Data Echo
This setting can be set ON or OFF. When set to ON, the data collection Q com
-
mands issued from the user’s PC will be displayed on the PC screen. When set
to OFF, these commands will not be displayed.
Содержание 96-8000
Страница 15: ...6 96 8000 Rev AC May 2010 Mill Warning Decals ...
Страница 16: ...7 96 8000 Rev AC May 2010 Safety Lathe Warning Decals ...
Страница 41: ...32 96 8000 Rev AC May 2010 ...
Страница 93: ...84 96 8000 Rev AC May 2010 ...
Страница 129: ...120 96 8000 Rev AC May 2010 ...
Страница 133: ...124 96 8000 Rev AC May 2010 ...
Страница 268: ......
Страница 269: ......