245
96-8000 Rev AC
May 2010
Maintenance
c
oolant
S
ySteM
M
aintenance
Chip Tray Cleaning
The most frequent interaction with the coolant tank will be with the chip tray.
Depending upon the type of material being milled, the chip tray may need to be
removed and cleaned a few times each day.
If the level sensor reads full, but the pumps begin to cavitate, the gate filter
needs to be cleaned. Pull the gate filter from the tank and tap it in the chip bar
-
rel or use an air hose to remove excess chips.
.
TSC
Pump
Standard
Pump
Float
Assembly
Filter
Retaining
Ring
Filter
Box
Filter
Screen
Remove Filter Screen for Cleaning
Gate
Filter
Handle
Tray
Chip
Tray
TSC Pump Filter
Pump removal (55 Gallon Tank Shown)
NOTE: The TSC pump has a filter, located in the bottom of the pump, that
also needs weekly cleaning.
The coolant tank should be cleaned monthly (weekly for TSC). The tank may
be pulled out from under the machine for better access by either lifting the
pumps from the tank (grasping the pump platform by the handles and lifting)
or removing power and disconnecting the hoses (keep a wrench in the handle
tray) and power cables, whichever is most convenient.
.
Standard
Pump
TSC
Pump
Gate
Filter
Handle
To
Spindle
Head
To
Spindle
Head
TSC
Filter
Gate
Filter
Level Sensor
Lid
Chip Tray
Single
Lid
Tank Movement (55 Gal. Tank shown)
Tank Component Removal
(55 Gal. Tank shown)
Содержание 96-8000
Страница 15: ...6 96 8000 Rev AC May 2010 Mill Warning Decals ...
Страница 16: ...7 96 8000 Rev AC May 2010 Safety Lathe Warning Decals ...
Страница 41: ...32 96 8000 Rev AC May 2010 ...
Страница 93: ...84 96 8000 Rev AC May 2010 ...
Страница 129: ...120 96 8000 Rev AC May 2010 ...
Страница 133: ...124 96 8000 Rev AC May 2010 ...
Страница 268: ......
Страница 269: ......