38
96-8000 Rev AC
May 2010
Copying Files
Highlight a file and press “Enter” to select it. A check mark appears next to the
file name.
Navigate to the destination directory with the arrow keys, press “Enter”, and
press F2 to copy the file.
Note that files copied from the control’s memory to a device will have the exten
-
sion “.NC” appended to the file name. However the name can be changed by
navigating to the destination directory, entering a new name, and then pressing
F2.
Duplicating a File
Press List Prog to access the Device Manager. Select the memory tab. Cur
-
sor to the program to duplicate, type a new program number (Onnnnn) and
press F2. The highlighted program is duplicated with the new name, and it is
made the active program. To duplicate a file to a different device, cursor to the
program name and press F2 without entering a new file name. A popup menu
lists destination devices. Select a device and press Enter to duplicate the file.
To copy multiple files, press Enter to place a check mark at each file name.
File Naming Convention
File names should be kept to a typical eight-dot-three format. For example:
program1.txt. However, some CAD/CAM programs use “.NC” as a file type rec
-
ognition, which is acceptable. File names can also be the same as the program
number with no extension, but some PC applications may not recognize the
file.
Files developed in the control will be named with the letter “O” followed by 5
digits. For example, O12345.
Renaming
To change the name of a file in USB or the Hard Drive, highlight the file, type a
new name and press “Alter”.
Deleting
To delete a program file from a device, highlight the file and press Erase Prog.
Delete multiple files by selecting them (press Enter to add a file to the selec
-
tion and place a check mark next to it; deselect by pressing Enter again), then
press Erase Prog to delete all selected files.
On-Screen Help
On-Screen help is available by pressing “HELP/CALC”. Select functions from
the popup menu and press “Enter” to execute, or use the hot key listed. To exit
the Help screen, press the “Cancel” button to return to the device manager.
RS-232
RS-232 is one way of connecting the Haas CNC control to another computer.
This feature enables the programmer to upload and download programs, set
-
tings and tool offsets from a PC.
Содержание 96-8000
Страница 15: ...6 96 8000 Rev AC May 2010 Mill Warning Decals ...
Страница 16: ...7 96 8000 Rev AC May 2010 Safety Lathe Warning Decals ...
Страница 41: ...32 96 8000 Rev AC May 2010 ...
Страница 93: ...84 96 8000 Rev AC May 2010 ...
Страница 129: ...120 96 8000 Rev AC May 2010 ...
Страница 133: ...124 96 8000 Rev AC May 2010 ...
Страница 268: ......
Страница 269: ......