program. The items in the menu can be selected with the Up and Down arrow
keys, or the jog handle. Enter the text, then press F3. Note: All pallets use the
same list of status items. Pressing F1 closes the menu without changing the
status of any of the pallets.
Resetting a status item to “User” is done by selecting an item from the menu
and pressing F4. All status items can be reset at the same time with the Origin
key.
Changing the status of an individual pallet can be done from the PST or with
the M49 command. In the PST, move the table cursor to the “Pallet Status”
column for the pallet desired. Press F1 for the status item menu. Use the ar
-
row keys to select the status, then press F2 or Write/Enter. See the previous
description of M49 and in the following examples for setting the pallet status
from a program.
CAUTION! The following commands can cause either rotary products to move:
Zero Return or Handle Jog
.
Load
Area
Machining
Area
M48 must be placed at the beginning of the program (or section of program)
that is run for the current pallet. This will check each time that a program is run,
that the program matches the pallet. For example:
Oxxxx (Users program)
M48
;
; (Users part program for pallet 1)
;
M30
Oxxxx (Users program)
M48
;
; (Users part program for pallet 2)
;
M30
An alarm will be generated, “A (or B) not in Position”, if the pallet in the ma
-
chine is not the one associated with the part program. If this alarm is gener-
ated, verify the correct program is running for the loaded pallet.
Содержание 96-8000
Страница 15: ...6 96 8000 Rev AC May 2010 Mill Warning Decals ...
Страница 16: ...7 96 8000 Rev AC May 2010 Safety Lathe Warning Decals ...
Страница 41: ...32 96 8000 Rev AC May 2010 ...
Страница 93: ...84 96 8000 Rev AC May 2010 ...
Страница 129: ...120 96 8000 Rev AC May 2010 ...
Страница 133: ...124 96 8000 Rev AC May 2010 ...
Страница 268: ......
Страница 269: ......