The Feed Hold button acts as an override, stopping rapid and feed moves
when it is pressed. The Cycle Start button must be pressed to proceed after a
Feed Hold. The door switch on the enclosure also has a similar result but will
display “Door Hold” when the door is opened. When the door is closed, the
control will be in Feed Hold and Cycle Start must be pressed to continue. Door
Hold and Feed Hold do not stop any auxiliary axes.
The operator can override the coolant setting by pressing the COOLNT button.
The pump will remain either on or off until the next M-code or operator action
(see Setting 32).
Overrides can be reset to defaults with an M06, M30 and/or pressing RESET
(See Settings 83, 87, 88).
d
iSPlay
K
eyS
Display keys provide access to the machine displays, operational information
and help pages. They are often used to switch active panes within a function
mode. Some of these keys will display additional screens when pressed more
than once.
Prgrm/Convrs -
Selects the active program pane in most modes. In MDI/DNC
mode, press to access VQC and IPS/WIPS (if installed).
Posit
(Position) - Selects the positions pane, located in the lower center of
most screens. Displays the current axis positions. Toggle between relative posi
-
tions by pressing the POSIT key. To filter the axes displayed in the pane, type
the letter for each axis to display and press WRITE/ENTER. Each axis position
is displayed in the order indicated.
Offset -
Press to toggle between two offsets tables. Select the Tool Offsets
table to display and edit tool length geometry, radius offsets, wear offsets, and
coolant position. Select the Work Offsets table to edit the G-code specified
work offset locations used in programs.
Curnt Comds
(
Current Commands) - Press PAGE UP / PAGE DOWN to cycle
through menus for Maintenance, Tool Life, Tool Load, Advanced Tool Manage
-
ment (ATM), System Variables, Clock settings and timer / counter settings.
Alarm / Mesgs
(Alarms /
Messages) - Displays the alarm viewer and message
screens. There are three alarm screens, the first shows the currently active
alarms (first press of the Alarm/Mesgs button). Press the Right Arrow key to
view Alarm History. Use the Up and Down Arrow keys to scroll through alarm
history entries, and press F2 to write to a memory device.
Param / Dgnos
(
Parameters / Diagnostics) - Displays parameters that define
the machine’s operation. Parameters are organized by category in a tabbed
menu, or to find a known parameter, type in the number and press the up or
down arrow. Parameters are set at the factory and should not be modified ex
-
cept by authorized Haas personnel.
Содержание 96-8000
Страница 15: ...6 96 8000 Rev AC May 2010 Mill Warning Decals ...
Страница 16: ...7 96 8000 Rev AC May 2010 Safety Lathe Warning Decals ...
Страница 41: ...32 96 8000 Rev AC May 2010 ...
Страница 93: ...84 96 8000 Rev AC May 2010 ...
Страница 129: ...120 96 8000 Rev AC May 2010 ...
Страница 133: ...124 96 8000 Rev AC May 2010 ...
Страница 268: ......
Страница 269: ......