237
96-8000 Rev AC
May 2010
Maintenance
The recommended method of attaching the air hose is to the barb fitting at the
back of the machine with a hose clamp. If a quick coupler is desired, use a 1/2"
coupler.
NOTE: Excessive oil and water in the air supply will cause the machine
to malfunction. The air filter/regulator has an automatic bowl dump that
should be empty before starting the machine. This must be checked for
proper operation monthly. Also, excessive contaminants in the air line
may clog the dump valve and cause oil and/or water to pass into the
machine.
NOTE: Auxiliary air connections should be made on the unregulated side
of the air filter/regulator.
WARNING! When the machine is operating and the pressure gauge
(on the machine regulator) drops by more than 10 psi during tool
changes or pallet changes, insufficient air is being supplied to the
machine.
M
aintenance
S
chedUle
The following is a list of required regular maintenance for the machining center.
These required specifications must be followed in order to keep the machine in
good working order and protect your warranty.
Interval
Maintenance Performed
Daily
• Check coolant level each eight-hour shift (especially
during heavy TSC usage).
• Check way lube lubrication tank level.
• Clean chips from way covers and bottom pan.
• Clean chips from tool changer.
• Wipe spindle taper with a clean cloth rag and apply light
oil.
Weekly
• Check Through the Spindle Coolant (TSC) filters. Clean
or replace if needed.
• Check for proper operation of auto drain on filter regula
-
tor.
Содержание 96-8000
Страница 15: ...6 96 8000 Rev AC May 2010 Mill Warning Decals ...
Страница 16: ...7 96 8000 Rev AC May 2010 Safety Lathe Warning Decals ...
Страница 41: ...32 96 8000 Rev AC May 2010 ...
Страница 93: ...84 96 8000 Rev AC May 2010 ...
Страница 129: ...120 96 8000 Rev AC May 2010 ...
Страница 133: ...124 96 8000 Rev AC May 2010 ...
Страница 268: ......
Страница 269: ......