58
Installing a UIS-RC-GPU/FHHL-2U-G3-F riser card and a
PCIe module
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Remove the PCIe riser card blank from PCIe riser connector 3, as shown in
.
5.
Install the PCIe module on the riser card:
a.
Remove the screw on the PCIe module blank in the target PCIe slot, and then pull the blank
out of the slot, as shown in
Figure 81 Removing the PCIe module blank
b.
Insert the PCIe module into the slot along the guide rails and use the screw to secure it into
place, as shown in
.
Figure 82 Installing the PCIe module
6.
Install the riser card bracket and use its screws to secure it into place, as shown in
.
7.
Insert the riser card in PCIe riser connector 3 and fasten the captive screw to the chassis air
baffle, as shown in
.