94
Figure 128 Removing the Mezzanine storage controller
9.
(Optional.) Remove the power fail safeguard module as needed. For more information, see
"
Replacing the power fail safeguard module for the Mezzanine storage controller
10.
Install the new Mezzanine storage controller and install the removed or a new power fail
safeguard module for the new Mezzanine storage controller as needed. For more information,
see "
Installing a Mezzanine storage controller and a power fail safeguard module
."
11.
Install the removed riser cards. For more information, see "
Installing riser cards and PCIe
."
12.
Install the removed fan cage. For more information, see "
."
13.
Install the removed air baffles. For more information, see "
14.
Install the access panel. For more information, see "
."
15.
Rack-mount the server. For more information, see "
16.
Connect the power cord. For more information, see "
17.
Power on the server. For more information, see "
Verifying the replacement
Log in to HDM to verify that the Mezzanine storage controller is in a correct state. For more
information, see HDM online help.
Replacing a standard storage controller
Procedure
1.
Power off the server. For more information, see "
2.
Remove the server from the rack. For more information, see "
Removing the server from a rack
."
3.
Remove the access panel. For more information, see "
."
4.
Remove the air baffles as needed. For more information, see "
."
5.
Remove the fan cage. For more information, see "
."
6.
Disconnect data cables that connect the standard storage controller to the drive backplane or
drive expander module.
7.
Disconnect the cable connected to the flash card on the standard storage controller.