Set up
comparator mode
5.
Use arrow keys to move cursor and
select
R-MODE
or
V-MODE
on the
[COMP SETUP] page.
Available options SEQ
SEQ comparison mode is used to compare
the upper and lower limits of the setting
range for voltage and resistance with the
measurement reading, so nominal value isn’t
required for calculation.
PER
(Measurement reading – nominal
value)/nominal value x 100%
ABS
Measurement reading – nominal value
Input normal
value
6.
Use arrow keys to select
R-NOM
or
V-NOM
on the [COMP SETUP]
page when comparator mode is set
to PER or ABS mode.