GBM-3080/3300 User Manual
14
Percent tolerance %TOL sorting: The percentage
deviation of the measured value from the
nominal value is compared with the limit of
each range.
Sequential sorting: The measured value is
directly compared with the upper and lower
limits setting.
Interface
RS-232 / USB remote control:
Support up to maximum 115200bps serial
transmission rate, compatible SCPI agreement
and ASCII transmission.
Handler I/O interface
All isolation with opt coupler. It equipped with
built-in input and output port to pull up
resistance.
Input: Trigger signal.
Output: All result signal after sorting
comparison, measuring synchronization signal
(EOC) and high current drive output which
directly drives relay.