4
IMPORTANT SAFETY INSTRUCTIONS
Secondary Means of Protection Against Entrapment
As specified by Underwriters Laboratories Inc. UL 325 (30A.1.1), automatic gate operators shall have provisions for,
or be supplied with, at least one independent primary and one independent secondary means to protect against
entrapment. GTO gate operators utilize Type A, an inherent (i.e., built-in) entrapment sensing system, as the primary
type of entrapment protection. The GTO/PRO 1000 series operators have provisions for the connection of Type B1
or B2 protection to be used as the secondary type of entrapment protection, if desired.
1. For gate operators utilizing a non-contact sensor (Type B1) in accordance with UL 325 (51.8.4 [h]):
A. Refer to the sensor manufacturer's instructions on the placement of non-contact sensors for each type of
application.
B. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while
the gate is still moving.
C. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as
the perimeter reachable by a moving gate or barrier.
2. For gate operators utilizing a contact sensor (Type B2) in accordance with UL 325 (51.8.4 [i]):
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post mounted both inside
and outside of a vehicular swing gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the
sensor and the gate operator is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for
entrapment protection functions shall be located where the transmission of the signals are not obstructed or
impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall
function under the intended end-use conditions.
ENTRAPMENT ALARM (UL 325; 30A.1.1A)
The GTO/PRO 1000 series operators are designed to stop and reverse for 2 seconds when the gate comes in
contact with an obstruction or when an object activates the non-contact sensors. Additionally, these operators
are equipped with an audio entrapment alarm which will function if the unit obstructs twice while opening
or closing. This alarm will sound for a period of 5 minutes or until the operator receives an intended signal
(e.g., transmitter signal) and the gate returns to a fully open or fully closed position.
R
E
D
B
L
K
O
R
G
B
L
U
G
R
N
C
L
S
E
D
G
O
P
N
E
D
G
R
E
D
G
R
N
O
R
G
B
L
U
W
H
T
B
L
K
O
R
G
B
L
U
G
R
N
C
L
S
E
D
G
O
P
N
E
D
G
LEARN
AUTO
CLOSE
INERTIA
STATUS
STATUS
BATT
+
–
OBSTR.
SENS.
RCVR
R G
B
ALAR
M
SECO
ND O
PERATO
R
FIRST OP
ERATO
R
POWER IN
18VAC
SOLAR
~ ~
– +
ACCE
SSORY
PWR. SW.
PWR. SW.
Entrapment Alarm
(bottom right of control box)